P CATEGORY LIGHTING — MAXIMUM SPACING TABLE
AS/NZS 1158.3.1:2020 (incl. Amd 1:2024)
Generated 9/7/2026, 9:13:24 AM

Luminaire: AFL110-HD, Street and Area Lighting     102-8062
Manufacturer: WE-EF     light source: 16 LED, Warm White - 120° angle of beam
I-table: 102-8062.ies     initial flux 3670 lm     maintenance factor 0.80
Spacing search 5–60 m in 0.1 m steps
Photometry: converted CIE I-table, 36 γ × 27 C, with I-table grid conventions
USER DEFINED LIMITS — not a standard lighting category. These spacings show compliance with the limits entered above, which are not those of AS/NZS 1158.3.1 Table 3.4.
Single-sided arrangement (Cl 3.3.6)     luminaire offset 0 m behind the path edge
Pathway surround: not assessed

User Defined — limits entered by the user, not a standard category
User Defined limits — Ēh ≥ 20 lx   EPh ≥ 20 lx   EPv ≥ 0 lx   UE2 ≤ 5

     H \ W        1      1.5        2
       2.4     15.4     15.7     16.2

A value marked + passed at the top of the search range and is a maximum
only up to that ceiling. Indicative design aid only.